Industrial OEM Static & Flow Water Sensing Module

 

This optical sensing module integrates dual operating modes for both static immersion and continuous water flow monitoring. It is engineered as a core sub-assembly for instrument manufacturers and system integrators requiring precise, real-time fluid parameter detection (e.g., turbidity, suspended solids, or specific optical density).
Working Principle: Modulated optical signals (LED or laser diode) pass through the fluid sample. A high-sensitivity photodiode measures the resulting scatter or absorption. Synchronous demodulation circuitry suppresses ambient light interference to maintain signal integrity.
Engineering Problem Solved: Eliminates the need for internal optical bench design, optical alignment, and analog front-end circuit development. It provides a pre-calibrated, sealed optical core that reduces host instrument development cycles by up to 6 months.

 
  • Static Water Module

    Point-Source Germicidal Illumination
    Direct Tank/Reservoir Mounting
    Customizable Aperture Sizes & Connectors
    Compact Circular Footprints
    Tailored Driver & Harness...

  • Water Flow Module

    Zero Flow Restriction Design
    Ultra-Compact Inline Form Factors
    Freeze-Shock Resistant Buffer Structure
    High Pressure & Temperature Tolerant
    NSF/ANSI 55 Compliant (Class B...

 
Module Types & Key Specifications

 

Specification

Static Immersion Model (S-Series)

Flow-Through Model (F-Series)

Primary Application

Open tanks, basins, boreholes, reservoirs

Inline pipelines, bypass loops, closed systems

Optical Source

850nm Infrared LED / 525nm Green LED

850nm Infrared LED / 525nm Green LED

Detector

Silicon Photodiode with integrated temperature compensation

Silicon Photodiode with integrated temperature compensation

Measurement Range

0 to 4000 NTU (selectable ranges)

0 to 4000 NTU (selectable ranges)

Accuracy / Repeatability

±2% of reading or ±0.5 NTU

±2% of reading or ±0.5 NTU

Communication Interface

RS485 (Modbus RTU protocol), SDI-12

RS485 (Modbus RTU protocol), 4-20mA analog

Operating Pressure

Ambient atmospheric pressure

Up to 0.6 MPa (6 bar)

Flow Rate Limit

N/A (Static body)

≤2.0 m/s

Ingress Protection

IP68 (Submersible up to 10 meters)

IP65 (Housing) / Wetted parts IP68

Power Supply

DC 9V to 36V

DC 9V to 36V

Dimensions

Ø45 mm × 185 mm

120 mm × 85 mm × 45 mm

Wetted Materials

316L Stainless Steel / POM

316L Stainless Steel / Quartz glass / Viton seals

 

Manufacturing & Quality Control

Production relies on strict process controls to ensure batch-to-batch optical consistency, regulatory compliance, and mechanical reliability:

Precision Machining

Optical chambers are CNC-machined from solid 316L stainless steel blocks to eliminate micro-porosity and prevent crevice corrosion.

Cleanroom Assembly

Optical components are bonded and aligned in an ISO Class 7 cleanroom environment to prevent dust or particulate entrapment in the optical path.

Quality Management & Compliance

Manufactured under an ISO 9001 certified quality management system. Electronics and assemblies comply with CE electromagnetic compatibility standards and RoHS hazardous substance restrictions.

Calibration & Aging

Every unit undergoes a 72-hour power burn-in test at 50°C and is multi-point calibrated using Formazin reference standards prior to packaging.

 

 

 

Applications & System Compatibility

Host Integration: Compatible with multi-parameter sondes, handheld field meters, industrial PLC systems, and IoT data loggers.


Communication Protocol: Modbus RTU over RS485 enables direct polling of raw/calibrated values, internal temperature, and diagnostic flags without external signal converters.


Operating Environment: Water temperature range from 0°C to 50°C; pH tolerance from 2 to 12.

Static Water Module

 

Customization & OEM/ODM Capabilities

 

 

Optical Customization

Alternative wavelength options (e.g., UV absorption or fluorescence excitation) available for specialized chemical or biological detection.

 

Mechanical Adaptation

Custom thread sizes (NPT, G, metric), flange fittings, or outer diameter constraints to fit specific host instrument chassis.

 

Firmware Modification

Customized sampling frequency, internal averaging algorithms, default baud rates, and custom Modbus register mapping.

 

 

Testing & Integration Support

 

 

Verification Protocols: Modules undergo hydrostatic pressure testing at 1.5x working pressure and thermal shock testing (-10°C to +60°C).
Technical Documentation Package: Supplied with electrical wiring schematics, complete Modbus register maps, and a NIST-traceable calibration certificate for each serial number.

 

 

Frequently Asked Questions

 

 

Q: How do I select between the static immersion model and the flow-through model?

A: Choose the S-Series (Static) for open channel, basin, or well deployments where the module is directly submerged. Choose the F-Series (Flow-Through) for inline pipe installations or bypass cabinets where fluid is pumped through a closed optical chamber.

Q: What is the standard sample lead time for evaluation?

A: Standard evaluation samples are stocked and ship within 3 business days upon order confirmation.

Q: Can the module output raw ADC counts alongside calibrated engineering units?

A: Yes. The Modbus register map provides access to both raw photodiode current counts and temperature-compensated engineering values (NTU/mg/L) for advanced host-side diagnostics.

Q: What is the recommended calibration interval?

A: Under normal municipal water conditions, the optical drift is less than 1% per 6 months. Field re-calibration is supported via zero-point and span-point Modbus command registers.

Q: How is batch-to-batch optical consistency maintained?

A: Each production batch uses matched LED emission spectra and photodiode pairings, followed by automated software gain normalization against baseline reference standards.

Q: What is the MOQ for custom mechanical interface modifications?

A: Minimum order quantities for customized mechanical housing or non-standard optical wavelengths start at 50 units per batch.

 

modular-1
Request a Quote

To request evaluation samples, custom engineering specifications, or volume pricing, please provide the following parameters:

Target Parameter & Range (e.g., 0–100 NTU)

Required Model Type (Static / Flow-Through)

Operating Pressure & Temperature Limits

Interface Protocol & Power Requirements

Estimated Annual Volume / Project Timeline

As one of the most professional static water/ water flow module manufacturers and suppliers in China, our products have good reputation in the market. Please rest assured to buy high quality static water/ water flow module at competitive price from our factory. For more information, contact us now.

Pipeline UV Disinfection Module, static water UVC LED sterilization modules, Water Purifier UV Module
Start Your UV LED Project with UVLEDTEK
Whether you need a standard UV LED or a custom configuration, our team can support you from product selection and technical evaluation to sampling and volume production.