Industrial High-Flow UV-C LED Water Disinfection System
Core Function
Continuous microbial inactivation of waterborne pathogens, including bacteria, viruses, Giardia, and Cryptosporidium, via germicidal UV-C radiation (λ = 265–280 nm).
Working Principle
Process water flows through a pressurized hydraulic reactor chamber where high-density UV-C LED arrays deliver a calculated germicidal fluence. The system neutralizes pathogens without chemical additives or disinfection byproduct (DBP) formation.
Solution Value
Replaces mercury-based low-pressure high-output (LPHO) lamps with solid-state UV technology, enabling instant power-switching, zero warm-up time, negligible thermal transfer to process water, and minimal hydraulic head loss.
-
5T/h High-Flow Water Disinfection Equipment
• Bactericidal efficacy greater than 99.99%
• The material of the water flow contact part adopts food safety grade
• Utilizes UV-LED light source with low light decay, environmental... -
3T/h High-Flow Water Disinfection Equipment
• Bactericidal efficacy greater than 99.99%
• The material of the water flow contact part adopts food safety grade
• Utilizes UV-LED light source with low light decay, environmental... -
Biomedicine and Chemical Synthesis
Uniform Illumination
Online Irradiance & Temperature Monitoring
Full Reaction Energy Profile Recording
Graded Alarms & Safety Interlocks
Multi-Level User Access...
System Types & Technical Specifications
|
Model Series |
Peak Flow Rate (m³/h) |
Min. UVT (%) |
Power Consumption (KW) |
Reactor Material |
Flange Standard |
|
HSU-500 |
500 |
≥ 90% |
3.2 |
316L Stainless Steel |
ANSI / DIN / JIS |
|
HSU-1000 |
1,000 |
≥ 90% |
6.5 |
316L / Titanium |
ANSI / DIN / JIS |
|
HSU-2000 |
2,000 |
≥ 85% |
13.0 |
316L / Titanium |
ANSI / DIN / JIS |
Design UV Dose: ≥ 40 mJ/cm² (at end-of-life and minimum UVT).
Operating Temperature Range: 1 °C to 40 °C (ambient), up to 50 °C (water inlet).
Maximum Operating Pressure: 1.0 MPa (Standard) / 1.6 MPa (Optional).
Applications & Industry Solutions
Municipal Drinking Water
Primary pathogen barrier disinfection for large-scale water treatment plants, achieving regulatory compliance without chemical residuals.
Industrial Process Water
Microbial control in ultrapure water (UPW) loops, semiconductor rinse systems, and pharmaceutical pre-treatment loops.
Wastewater Tertiary Treatment
Disinfection of secondary effluent prior to environmental discharge or agricultural reuse.
Aquaculture (RAS)
Pathogen reduction in recirculating aquaculture systems to control viral and bacterial outbreaks without altering water chemistry.
Reactor Assembly: Computational Fluid Dynamics (CFD)-optimized chamber geometry ensuring uniform dose distribution and eliminating hydraulic dead zones.
Cleaning Mechanism: Integrated automated mechanical quartz wiper assembly with pneumatic drive to prevent inorganic scaling and biological fouling on quartz sleeves.
Control Panel: Siemens S7-1200 PLC with a 7-inch industrial HMI touchscreen, supporting Modbus TCP, Profinet, and 4–20 mA analog outputs for real-time monitoring of UV intensity, flow rate, and alarm status.
Power Distribution Unit (PDU): Enclosed in a NEMA 4X / IP65 stainless steel cabinet with active thermal management and individual LED driver channel monitoring.

Performance Validation & Service
Manufacturing & Quality Control:
Reactor chambers formed via CNC laser cutting and automated robotic TIG welding.
Interior wetted surfaces mechanically polished and electro-polished to an average roughness of Ra ≤ 0.4 μm, followed by acid passivation.
Each pressure vessel undergoes 1.5x hydrostatic pressure testing and helium mass spectrometer leak detection prior to factory exit.
Validation Standards: Radiometric output tested against NIST-traceable standards; CFD hydraulic verification models available upon request.
Technical Support: Comprehensive Installation, Operation, and Maintenance (IOM) manuals, factory acceptance testing (FAT) documentation, and on-site or remote commissioning supervision by application engineers.
Frequently Asked Questions

Request a Quote
To receive a formal technical proposal and commercial quotation, please provide the following parameters to our engineering team:
Peak and Average Flow Rate: m³/h or GPM
Water Transmittance: UVT % at 254 nm
Target Pathogen and Required Log Reduction
Inlet/Outlet Pipe Size and Flange Standard
Target Operating Pressure and Water Temperature
Submit your inquiry via our engineering contact portal to receive a response with preliminary CFD flow data and equipment footprint drawings within 24 hours.
As one of the most professional system manufacturers and suppliers in China, our products have good reputation in the market. Please rest assured to buy high quality system at competitive price from our factory. For more information, contact us now.