Industrial High-Flow UV-C LED Water Disinfection System
 

Core Function

Continuous microbial inactivation of waterborne pathogens, including bacteria, viruses, Giardia, and Cryptosporidium, via germicidal UV-C radiation (λ = 265–280 nm).

Working Principle

Process water flows through a pressurized hydraulic reactor chamber where high-density UV-C LED arrays deliver a calculated germicidal fluence. The system neutralizes pathogens without chemical additives or disinfection byproduct (DBP) formation.

Solution Value

Replaces mercury-based low-pressure high-output (LPHO) lamps with solid-state UV technology, enabling instant power-switching, zero warm-up time, negligible thermal transfer to process water, and minimal hydraulic head loss.

 
  • 5T/h High-Flow Water Disinfection Equipment

    • Bactericidal efficacy greater than 99.99%
    • The material of the water flow contact part adopts food safety grade
    • Utilizes UV-LED light source with low light decay, environmental...

  • 3T/h High-Flow Water Disinfection Equipment

    • Bactericidal efficacy greater than 99.99%
    • The material of the water flow contact part adopts food safety grade
    • Utilizes UV-LED light source with low light decay, environmental...

  • Biomedicine and Chemical Synthesis

    Uniform Illumination
    Online Irradiance & Temperature Monitoring
    Full Reaction Energy Profile Recording
    Graded Alarms & Safety Interlocks
    Multi-Level User Access...

 
System Types & Technical Specifications

 

Model Series

Peak Flow Rate (m³/h)

Min. UVT (%)

Power Consumption (KW)

Reactor Material

Flange Standard

HSU-500

500

≥ 90%

3.2

316L Stainless Steel

ANSI / DIN / JIS

HSU-1000

1,000

≥ 90%

6.5

316L / Titanium

ANSI / DIN / JIS

HSU-2000

2,000

≥ 85%

13.0

316L / Titanium

ANSI / DIN / JIS

 

Design UV Dose: ≥ 40 mJ/cm² (at end-of-life and minimum UVT).

Operating Temperature Range: 1 °C to 40 °C (ambient), up to 50 °C (water inlet).

Maximum Operating Pressure: 1.0 MPa (Standard) / 1.6 MPa (Optional).

 

Applications & Industry Solutions

Municipal Drinking Water

Primary pathogen barrier disinfection for large-scale water treatment plants, achieving regulatory compliance without chemical residuals.

Industrial Process Water

Microbial control in ultrapure water (UPW) loops, semiconductor rinse systems, and pharmaceutical pre-treatment loops.

Wastewater Tertiary Treatment

Disinfection of secondary effluent prior to environmental discharge or agricultural reuse.

Aquaculture (RAS)

Pathogen reduction in recirculating aquaculture systems to control viral and bacterial outbreaks without altering water chemistry.

 

 

Configuration & Customization

Reactor Assembly: Computational Fluid Dynamics (CFD)-optimized chamber geometry ensuring uniform dose distribution and eliminating hydraulic dead zones.


Cleaning Mechanism: Integrated automated mechanical quartz wiper assembly with pneumatic drive to prevent inorganic scaling and biological fouling on quartz sleeves.


Control Panel: Siemens S7-1200 PLC with a 7-inch industrial HMI touchscreen, supporting Modbus TCP, Profinet, and 4–20 mA analog outputs for real-time monitoring of UV intensity, flow rate, and alarm status.


Power Distribution Unit (PDU): Enclosed in a NEMA 4X / IP65 stainless steel cabinet with active thermal management and individual LED driver channel monitoring.

5T/h High-Flow Water Disinfection Equipment

 

Performance Validation & Service

 

 

Manufacturing & Quality Control:
Reactor chambers formed via CNC laser cutting and automated robotic TIG welding.
Interior wetted surfaces mechanically polished and electro-polished to an average roughness of Ra ≤ 0.4 μm, followed by acid passivation.
Each pressure vessel undergoes 1.5x hydrostatic pressure testing and helium mass spectrometer leak detection prior to factory exit.
Validation Standards: Radiometric output tested against NIST-traceable standards; CFD hydraulic verification models available upon request.
Technical Support: Comprehensive Installation, Operation, and Maintenance (IOM) manuals, factory acceptance testing (FAT) documentation, and on-site or remote commissioning supervision by application engineers.

 

 

Frequently Asked Questions

 

 

Q: How is the UV reactor sized for variable water transmittance (UVT)?

A: System sizing is governed by the design peak flow rate, minimum operational UVT (%), and required target pathogen log reduction (e.g., 4-log virus inactivation). Lower UVT values require increased UV-C output density and adjusted reactor residence times.

Q: What is the operational lifespan of the UV-C LED modules?

A: The LED modules are rated for an L70 operational life of 50,000 hours under rated thermal and electrical operating conditions. Modules are field-replaceable without draining the main process pipeline.

Q: How does the system prevent fouling on the quartz sleeves?

A: An automated mechanical wiper ring cycles across the quartz sleeves at programmable intervals, removing suspended solids, mineral scale,

Q: What are the standard lead times for manufacturing and delivery?

A: Standard industrial reactor systems require 8 to 12 weeks from technical drawing sign-off to factory shipment.

Q: What documentation is provided for Factory Acceptance Testing (FAT)?

A: Each system includes material test reports (MTRs) for wetted metallic parts, hydrostatic test certificates, weld inspection records (surface passivation and roughness test reports),

Q: Can the control system integrate into an existing plant SCADA network?

A: Yes. The standard PLC control architecture supports Modbus RTU, Modbus TCP, and Profinet communication protocols,

 

modular-1
Request a Quote

To receive a formal technical proposal and commercial quotation, please provide the following parameters to our engineering team:

Peak and Average Flow Rate: m³/h or GPM

Water Transmittance: UVT % at 254 nm

Target Pathogen and Required Log Reduction

Inlet/Outlet Pipe Size and Flange Standard

Target Operating Pressure and Water Temperature

Submit your inquiry via our engineering contact portal to receive a response with preliminary CFD flow data and equipment footprint drawings within 24 hours.

 

As one of the most professional system manufacturers and suppliers in China, our products have good reputation in the market. Please rest assured to buy high quality system at competitive price from our factory. For more information, contact us now.

Start Your UV LED Project with UVLEDTEK
Whether you need a standard UV LED or a custom configuration, our team can support you from product selection and technical evaluation to sampling and volume production.