LD2MQFB UVC LED LED package
Product Model | LD2MQFB |
Product Category | UVC LED LED package |
The world's first | polymer materials UVC |
reliability | Comparable to ceramic bracket products |
cost | Decreased over 10% |
Product documentation |
Product Features
Application scenarios
air purifier UVC LED LED package UVLEDTEK relies on professional UV technology, Provide efficient air purifiers UVLED Sterilization light source, Effectively purify the air, Inhibit bacterial growth. Choose UVLEDTEK, Create a fresh and healthy air environment for you.
Mother and baby room・Aseptic respiratory protection: Baby's respiratory system is fragile, UVC LED The module targeted disinfection and sterilization of bacteria in the milk powder tank, Paired with low-noise operation, Make the air in the mother and baby room cleaner, Reduce neonatal eczema, Cough risk. office・Virus firewall: High risk of cross infection among multiple people in the conference room, UVC LED The module quickly disinfection and sterilization the residual virus in droplets, Adapt to desktop purifiers, Let the office air improve "Can disinfect" , Efficiency doubled. Pet Home・farewell "fur baby" odor: pet dander, Urine odor hides dirt and grime, UVC LED Module decomposition odor molecules, Kill cat ringworm fungi, etc, The close contact between the poop shoveler and the pet is more reassuring.
Basic Parameters
parameter name | parameter value |
---|---|
optical power | 4-10 mW |
drive current | 40 mA |
wavelength | 260~280 nm |
Light output angle | 120° |
Package Size | 3535 |
Substrate material | polymer materials |
Lens Material | sapphire |
ambient lighting | UVA |
structural dimensions
Device size
circuit connection
Detailed specifications
@40mA (Ta = 25℃, RH=40%)
parameter |
test conditions |
symbol |
numerical value |
grading |
unit |
||
minimum |
typical value |
maximum |
|||||
UVCpeak wavelength |
If=40 mA |
WLP |
260 |
|
280 |
10 |
nm |
Half wave width |
If=40 mA |
Δλ |
7 |
|
13 |
/ |
nm |
optical power |
If=40 mA |
Po |
3 |
|
10 |
/ |
mW |
UVCWorking Voltage |
If=40 mA |
Vf |
5 |
|
7 |
0. 1 |
V |
beam angle |
If=40 mA |
2θ1/2 |
110 |
120 |
130 |
/ |
Deg |
Reverse leakage |
Vr=4 V |
Ir |
0 |
|
1 |
/ |
μA |
thermal resistance |
If=40 mA |
Rth (j-s) |
|
≤20 |
|
|
℃/W |
wavelength range:
gear |
W01 |
W02 |
scope (nm) |
260~270 |
270~280 |
Optical power range:
gear |
P032 |
P024 |
P025 |
scope (mW) |
3~6 |
6~8 |
8~10 |
voltage range:
gear |
V11 |
V12 |
V13 |
V14 |
V15 |
V16 |
V17 |
scope (V) |
5. 0~5. 1 |
5. 1~5. 2 |
5. 2~5. 3 |
5. 3~5. 4 |
5. 4~5. 5 |
5. 5~5. 6 |
5. 6~5. 7 |
gear |
V18 |
V19 |
V1A |
V1B |
V1C |
V1D |
V1E |
scope (V) |
5. 7~5. 8 |
5. 8~5. 9 |
5. 9~6. 0 |
6. 0~6. 1 |
6. 1~6. 2 |
6. 2~6. 3 |
6. 3~6. 4 |
gear |
V1F |
V1G |
V1H |
V1I |
V1J |
V1K |
|
scope (V) |
6. 4~6. 5 |
6. 5~6. 6 |
6. 6~6. 7 |
6. 7~6. 8 |
6. 8~6. 9 |
6. 9~7. 0 |
|
1. 2 UVAOptoelectronic parameters (Ta=25℃, RH=40%)
parameter |
symbol |
numerical value |
unit |
UVApeak wavelength |
λp |
395-405 |
nm |
UVARadiation flux |
Po |
30-100 |
mW |
UVAdrive current |
If |
40-150 |
mA |
UVAWorking Voltage |
Vf |
3. 0-4. 0 |
V |
1. 3 Extreme conditions
parameter |
symbol |
numerical value |
unit |
power consumption |
Pd |
560 |
mW |
forward current |
If |
80 |
mA |
forward voltage |
Vf |
5~7 |
V |
Operating Temperature |
Topr |
-30~85 |
℃ |
Storage temperature |
Tstg |
-40~100 |
℃ |
junction temperature |
Tj |
≤110 |
℃ |
static electricity (HBM) |
ESD |
2000 |
V |
data curve
Reliability project
test project |
Relevant standards |
test conditions |
test cycle |
Failure Criteria |
Number of failures |
Room temperature aging |
JEDEC JESD22 A108. C |
Ta=25 ℃, If =40 mA Rthja=22 ℃/W |
1000 hour |
ΔPo' 15% ΔVF' 10% |
0/10 |
thermal shock |
JEDEC JESD22-A104 |
-40 ℃to100 ℃Temperature changes, 30 mina cycle |
300time |
0/10 |
|
anti-static |
ANSI/ESDA/ JEDEC JS-001 |
HBM , 2 KV, 1. 5 kΩ, 100 pF, 3 pulses |
|
0/50 |
|
vibration |
JEDEC JESD22-B110 |
200 m/s2, 20 Hz , x. y. z Three directions |
24hour |
0/10 |
|
Low-temperature storage |
EIAJED4701/200 (202) |
Ta=-40 ℃ |
1000hour |
0/10 |
|
high temperature storage |
EIAJED4701/200 (201) |
Ta=100 ℃ |
1000hour |
0/10 |
|
Anti reflux |
EIAJED4701/300 (304) |
Peak≤260 ℃, 10Temperature zone reflux |
1time |
0/100 |
Frequently Asked Questions
Youweixin provides professional pre-sales and after-sales consultation and services. We will recommend the most suitable one based on your needs UVLED product. If you have any questions, Please feel free to send us an email at any time:
info@uvledtek. com
Due to the large number of emails received every day, And the time zones are different, We may not be able to reply to your email immediately. But we will 24 Reply to your inquiry within one working hour.
Core components
more UVC LED Lamp bead products

LP2MQBBUVC LED LED package
Product Features: high reliability, long lifespan, environmental protection and energy conservation, 120°Light output angle; Application field: Sterilization, Medical phototherapy, optical sensor, bioanalysis/detection.

LP2AQHBUVC LED LED package
Product Features: high reliability, long lifespan, environmental protection and energy conservation, 120°Light output angle; Application field: Sterilization, Medical phototherapy, optical sensor, bioanalysis/detection.

LP2AHACUVC LED LED package
Product Features: high reliability, long lifespan, environmental protection and energy conservation, 30°Light output angle; Application field: Sterilization, Medical phototherapy, optical sensor, bioanalysis/detection.

LP2AHAAUVC LED LED package
Product Features: high reliability, long lifespan, environmental protection and energy conservation, 60°Light output angle; Application field: Sterilization, Medical phototherapy, optical sensor, bioanalysis/detection.

LM218QQAUVC LED LED package
Product Features: high reliability, long lifespan, environmental protection and energy conservation, Ultra-high optical power, Concentrated high-efficiency sterilization; Application field: Sterilization, Medical phototherapy, optical sensor, bioanalysis/detection.
We need this product?
You can obtain business and technical consultation through the following methods